LRC CALIBRATION
In some cases, you may need to calibrate the Digital
Timepiece to work properly with a specific LRC. If
your LRC is not working as it should with the
Digital Timepiece, try the procedure below.
Two pots on the Digital Timepiece circuit board
can be used to calibrate it for an LRC. As the front
of the Digital Timepiece is facing you, the pot on
the right is the RANGE pot. The pot on the left is
the OFFSET pot. To view the LRC value, use a
video monitor connected to the Digital Timepiece
VIDEO OUT, and turn on the video display with
ClockWorks.
1 Set the RANGE pot and the OFFSET pot to their
midpoint position.
2 Plug in your LRC and adjust the OFFSET pot to
4. Slowly turn the OFFSET pot clockwise until the
LRC value readout on the video monitor just
begins to hold steady at 3.
3 Press the ALL INPUT MONITOR button on the
LRC. (This is the top left button on LRC if you are
using a third-party brand.)
4 Adjust the RANGE Pot for an LRC value
readout that toggles between 59 & 60.
5 Press the LRC’s RECORD button.
6 Set OFFSET pot so that LRC video readout
toggles between 6 & 7.
At this point, it is normal for the idle value (no
buttons pressed) to be 3 or 4.